    fuling inverter manual

    Current Inspection Circuit Failure(E015) Whether it is normal after the C hange Hall device C heck if Hall device is normal main control board fault renewal of the main control board Check if the drive board is normal. The frame includes frame error det ection field calculated on the basis of This part is the defini tion of the communication data addre ss, used to control inverter operation, and CRC. S tan d a r d E x te nsio n Ca bl e: Le n g t h Mo d e l ne t w o rk c a b le c o m p an y na me 3. We have 2 Fuling Inverter DZB300 Series manuals available for free PDF download: User Manual Open-loop vector control inverter. Ge tting Started This manual will be helpful in the installation, parameter setting, troubleshooting, and daily maintenance of the AC motor drives. To guarantee safe operation of the equipment, read the fo llowing safety guideline s before connecting power to the AC drives. Keep this operating manual handy an d distribute to all users for refere nce. ! WARNINGATTENTION: Always read this manual thoroughly before using DZB series AC Motor Drives. DANGER! AC input power must be disconnected before any maintenance. WARNING! Do not c onnect or disconnect wires and connectors while power is applied tothe circuit.Maintenance must be performed by qualified technicians. The DC-link capacitor remains charged with a ha zardous voltage even after input power is removed. ATTENTION: Grounding the DZB100B drive is done by c onnecting the Earth Ground to the driveground terminal. CAUTION: There are highly sensitive components on the printed circuit boards. These components areespecially sensitive to ESD (electrostatic discharge). To avoid damage to the drive,do not touch components or the circuit boards until static control precautions have been taken. CAUTION: Never connect the main circuit output terminals U, V, and W directly to the AC main circuitpower supply as this will damage the drive.

    • fuling inverter manual, fuling inverter manual pdf, fuling vfd manual, fuling inverter dzb300 manual, fuling inverter dzb manual, fuling inverter dzb200 user manual, fuling inverter dzb 312 manual pdf, dzb series fuling inverter manual, fuling inverter dzb 312 manual, fuling inverter dzb 280 manual, fuling inverter manual, fuling inverter dzb 280 manual.

    Ge tting Started This manual will be helpful in the installation, parameter setting, troubleshooting, and daily maintenance of the AC motor drives. Special Usages The user can consult our company if he wants to use another method instead of the recommended Chapter 2 Product Introduction connecting method provided in the manual, such as shared DC bus. 12. The difference is: pressing DATA will save the parameters and return to second le vel menu and then shift to the next function c ode, while pressing PRG will return to second level menu without saving the Displayed. Able to set up frequency command, and memorize 6 Remote communication this set frequency when the inverter is power down. When the power is back,automatically combine it with The frequency command is given in the communication mode by upper position machine.For details, “. Inverter will not run if it detect operating command terminal O u tp u t F r e q u e n c y f is valid. At this mode EN is the Enable terminal, SW1 or external terminals. Output fre quency Traverse frequency function means that the inverter output frequency is traversing up and down around FDT delay the set frequency. Func tio n Default Setting Range Name Cod e Value This parameter is to determine the assignment channel of the proce ss PID target value. The bigger the P, the bigger Function Default Setting Range N ame Code Value the adjusting strength is.Once the fault occurs, Transient powe r cut exists or not motor driver inverter reset the protection function starts, the inverter stops inputting, the fault relay contact point is activated, and the. Over voltage during deceleration(E00A) Adjust the voltage within The motor protection parameter The input voltage is too high or not Correctly set up the parameter normal range F5.01 setting is suitable or not. EEPROM read-write failure(E00F) 16.

    Wiring can only be done after the mains input is cut off, otherwise there will be danger of electric shock. Please connect the inverter to the ground according to the standard, otherwise there will be danger of electric shock. Do not open the cover of the inverter after power-on, otherw ise there will be danger of electric shock. Do not touch the inverter and its circuit with wet hand, other wise there will be danger of electric shock. Do not touch the inverter terminals, otherw ise there will be danger of electric shock. At power-on, the inverter will perform the security check of the external heavy-current circuit automatically, so at this time please do not touch the terminals U, V and W, or the terminals of motor, otherwise there will be danger of electric shock. - 1- - 2- DZB Series Chapter 1 Safety and Cautions DZB Series Chapter 1 Safety and Cautions 1.2 CautionsNote 1. Check the Insulation of the Motor If parameter identification is required, please pay attention that the rotating motor may injure people, otherwise ac cident may occur. Do not change the factory settings, otherwise the inver ter may be damaged. When the motor is used for the first time, or reused after storing for a long time, or in regular checkup, the user mus t check the insulation of the motor to prevent the poor insulation of the windings of motor from damaging the inverter. The motor connection must be divided from the inverter during the insulation che ck. Please consider the capability of the mechanical devices whe n the customer needs the inverter to run at the frequency higher than 50Hz. 4. Motor He at and Noise Since the output voltage of the inverter is in PWM wave with some harmonics, the temperature may rise, the noise and vibration may increase compared with the inverter running at main frequency. 5.

    CAUTION: Do not apply the antirust to screws for fastening drives; Please cle an the drives and screwswith dry c loth or alcohol, not with synthetic cleaner. Fasten the screws with washers and rated torque lest the enclosure corners of drive s be distorted. Operations which are not performed according to requirements may cause moderate hurt or light hurt or equipment damage. Danger Do not connect the input terminals with the output termina ls (U, V, W), otherw ise the inverter may be damaged. Ens ure the wiring mee t the EMC requirements and the local safety standard. The wire size shall be det ermined according to the manual, otherwise accident may occur. Pleas e confirm the mains voltage level is c onsistent with that of the inverter and the input and output wirings are correct, and check if there is any short circuit in peripheral circuit and if the wiring is fixed and fast, otherwise the inverter may be damaged. Mount the cover plate properly before power-on the inverter, otherwise there will be danger of electric shock. 2.During InstallationDanger Note Mount the inverter on incombustible surface like metal, and keep awa y from flammable substances. Otherwise it may cause fire. Note Dielectric strength test had been done at factory. Therefore, user needs not do this test again, otherwise accident may occur. All the peripheral parts shall be connected correctly according to the manual, or accident may occur. When more than two inverters are to be installed in one cabinet, ple ase pay attention to the installation locations to ensure the cooling effect (refer to Chapter 3 Mechanical and Ele ctrical Installation). Do not drop the lead wire stub or screw in the inverter, or the inverter may be damaged. 5.After Power-on Danger 3.WiringDanger Only the qualified electrical engineer can perform the wiring, otherwise there will be danger of electric shock. A circuit breaker must be installe d between the mains and the inverter, otherwise there w ill be danger of fire.

    Running Danger Do not approach the equipment when restart function is enabled, otherwise there w ill be danger of injury. Do not touch the fan and the discharging resistor to check the temperature, otherwise burning may occur. Discover everything Scribd has to offer, including books and audiobooks from major publishers. Start Free Trial Cancel anytime. Report this Document Download Now Save Save Fuling Inverter User Manual For Later 100% (5) 100% found this document useful (5 votes) 14K views 54 pages Fuling Inverter User Manual Uploaded by Fayzan Hannan Description: Full description Save Save Fuling Inverter User Manual For Later 100% 100% found this document useful, Mark this document as useful 0% 0% found this document not useful, Mark this document as not useful Embed Share Print Download Now Jump to Page You are on page 1 of 54 Search inside document Browse Books Site Directory Site Language: English Change Language English Change Language. Page 5 DZB Series DZB Series Chapter 1 Safety and Cautions Chapter 1 Fuling inverter DZB300 Series Pdf User Manuals. View online or download Fuling inverter DZB300 Series User Manual. 26 Jun 2014. To start viewing messages,I found an english manual online, but I can't seem to get it into the programming mode so I can change over to terminal control. But it won't do anything. I can't scroll through the sub menus. The manual mentions a password but the unit never asks for a password (not that I've set one up). It should hopefully be factory default settings but I can't find anything about to reset it anyway. Does anyone have any ideas with the beast.Oh well I'll just keep doing it all manual for now. I've tried emailing Fuling but their emails just bounce back again. Cheers anyway Matt But for now this is just a project. Please tell me if you are solving this issue and if your connection with Mach3 is working.

    Pressure-sensitive Device or Capacitor at the Output Side of the Inverter Because the inverter outputs PWM wave, the capacitor used for improving power factor and pressuresensitive res istor used for lightening-proof shouldn't be installed at the output side of the inverter, otherwise the inverter may have transient over-current and may be damaged. 6. Switches Used at the Input a nd Output terminal of the Inverter If the contactor is required to be installed betw een the inverter and the power supply, it is prohibited to start or stop the inverter with the contactor. If the user has to use the contactor to start a nd stop the inverte r, the interval between the start and stop shall be less than one hour. Frequent charging and discharging ma y reduce the life of the capacitor. If the switches like contactors are connected between the output terminal and the motor, make sure to start and stop the inverter when the inverter has no output, otherwise the modules in the inverter may be damaged. 7. Usage Outside the Range of Rated Voltage The DZB series inverter shall not be used out of the specified range of operation voltage, otherwise the internal components of the inverter may be damaged. If needed, please use corresponding voltage regulation device to change the voltage. 8. 3-phase Input Modified Into 2-phase Input The modification of DZB series inverter from 3-phase input to 2-phase input is not allowed, or fault may occur. 9. Lightning Strike Protection There are lightning protection devices inside the inverter, But the user should install other lightning protection device at the front end of the inverter if lightning strike occurs frequently. 10. Altitude and Deration When the altitude is higher than 1000m, the cooling effect of inverter is deteriorated because of the rarefaction of air, the deration must be used and please consult our company for detailed technical support. 6.

    Hello, I need the Manuel for DZB312B003?.7L2DK. Manual and User Guide for many equipments like mobile phones, photo cameras, motherboard, monitors, software, tv, dvd, and others. I found manuals that contain only. I'm using a mix of Hitachi, Siemens, Omron and ABB drives in my workshop, they are more expensive than the Chinese equivalents but the manuals are written in english, which for me makes them worth the extra as my Chinglish isn't very good;-) Regards, Nick. Hopefully you can make sense of it. Only info I have are photos attached. Hopefully you can make sense of it. I'll fix and re-send. I'll fix and re-send. Refer to page 8 of the PDF file. Refer to page 8 of the PDF file. Showing recent items. Sunday, Sep 27Tomorrow Our payment security system encrypts your information during transmission. We don’t share your credit card details with third-party sellers, and we don’t sell your information to others. To hide it, choose Ship in Amazon packaging at checkout.Please try again.Register a free business account Exclusive access to cleaning, safety, and health supplies. Create a free business account to purchase In order to navigate out of this carousel, please use your heading shortcut key to navigate to the next or previous heading. Please try your search again later.You can edit your question or post anyway.Page 1 of 1 Start over Page 1 of 1 In order to navigate out of this carousel, please use your heading shortcut key to navigate to the next or previous heading. In order to navigate out of this carousel, please use your heading shortcut key to navigate to the next or previous heading. To calculate the overall star rating and percentage breakdown by star, we don’t use a simple average. Instead, our system considers things like how recent a review is and if the reviewer bought the item on Amazon. It also analyzes reviews to verify trustworthiness. Attention: ? Al ways read this manual thoroughl y before using DZB series A C Motor Drives. ?

    Do not connec tSep 11, 2018 - the following safety guidelines before connecting power to the AC drives. DZB200 inverter provides password protection for users. Fuling inverter DZB200 Series Pdf User Manuals. View online or download Fuling inverter DZB200 Series User Manual. View and Download Fuling Inverter DZB200 Series user manual online.Excitation Mar 19, 2010 -. Our payment security system encrypts your information during transmission. We don’t share your credit card details with third-party sellers, and we don’t sell your information to others. To hide it, choose Ship in Amazon packaging at checkout. To hide it, choose Ship in Amazon packaging at checkout. Please try again.Please try again.In order to navigate out of this carousel please use your heading shortcut key to navigate to the next or previous heading. Register a free business account Please try your search again later.To calculate the overall star rating and percentage breakdown by star, we don’t use a simple average. It also analyzes reviews to verify trustworthiness. Please try again later. Mark Ottman 5.0 out of 5 stars In order to navigate out of this carousel please use your heading shortcut key to navigate to the next or previous heading. Inching operation: frequency range: 0.0Hz-Maximum output frequency Inching acceleration and deceleration time: 0-3600.0s 13. Simple PLC and multistage speed operation: it can realize up to 8 segments running 14. Automatic voltage regulation: When grid voltage fluctuation occurred, it can automatically maintain constant output voltage. Product Photos Please feel free to contact us for more information.Inching operation: frequency range: 0.0Hz-Maximum output frequency Inching acceleration and deceleration time: 0-3600.0s 13. Simple PLC and multistage speed operation: it can realize up to 8 segments running 14. Product Photos Please feel free to contact us for more information. Did you miss your activation email ? The manual for the VFD, a Fuling DZB200B002.

    I hope I'll be able to support this thread but this will happen just after I'll finish my router and have anything in place and working. Best regards, Seb I was able to get it into terminal mode. I still have some different firmware I guess though because the table was slightly different. But I was only after terminal mode which worked ok for me. The default contacts allow me to remotely select the run forward command which is all I'm after. Hope you have fun! Let me know how you go with RS485. Cheers Matt I cannot test it yet in Communication mode because the RS485 adapter doesn't arrive. In the mean time I've read the manual and some topics about the Huanyang inverter ( Huanyang VFD controller plugin ) and I suppose following: The Fuling inverter should be set up just like the Huanyang inverter, with the same Mach3 plugin, we just have to find the correct settings for it. The inverter have to work in Communication mode (through RS485), not Terminal mode, I think. I repeat, I doesn't test it yet, I'll do it right after I'll have the RS485 adapter. Until then, I'm wondering about one setting: F0.01 If F0.01 will be 2 (Communication) instead 0 (Keyboard, default), I will lose the keyboard control over the VFD. How can I will return to the Keyboard mode. I'm a little bit scared about this parameter. Best Regards The ModIO plugin for Mach3 is reading the VFD's parameters without problems. For now, I have to find out how to control the spindle through Mach3 because with the default settings don't work. For now, I have the VFD successfully connected through the RS485 line and Mach3's Modbus can read any serial address from VFD. Could somebody give me some advices? Thanks. I cannot figure why the JOG command doesn't work. Communication setting address (page 95) is used for setting the running frequency (speed). If somebody is interested, please ask.

    Regards, Seb I've just decided I need to control speed myself, and maybe it's worth investing in a RS-485 adaptor to achieve this. It seems like MODBUS should be easy enough (well after hearing from you anyway). Matt Cheers - Matt Which RS-485 adaptor are you using? Thank you So, the brains I've made are attached. Vfdrun.brn is used for sending commands like RUN and STOP Vfdspeed.brn is used for sending speed's parameters. I also attach the modbus settings. I think that's all. For any issues, please ask. Any hints and suggestions are welcome. Regards, Seb Looking at the values in the P registers (my VFD has P00 to P157) I found that a manual for a DZB100 was the closest match. e.g parameter 0-5 match and parameters 7 to 23 on the vfd match 6 to 22 in the manual. Switching p76 to 0 allowed me to adjust other settings. The router I have is controlled from NCstudio and it looks like it was wired so it can only set 2 speeds (rather than 7) and was maxing out the freq at 150 which only gives 9000rpm (measured with a laser tachometer). Tweaking P18 allows me to get set a higher speed. Now that I know how to tweak the VFD it means I can switch the router over to mach3 otherwise plan B would have been to swap the VFD for something which does have a useful manual. I never get too far with mine and usually end up doing something else instead. I might one day look for the other manual like you said. The problem is finding the time to do it when the benefits aren't that important to me. Cheers - Matt The site is 100% free to join and use, so join today! Thank you! Fuling Inverter DZB300 Series User Manual (54 pages) dzb300 series High-performance general-purpose inverter, open-loop vector control inverter. 26 Jun 2014 please refer to this operation manual before using. This inverter uses advanced IGBT silent design combining with vast technology over the years to complete DZB200 Series Inverter pdf manual download. Related Manuals for Fuling Inverter DZB200 Series.

    2L2DK, is available at A photo of the VFD with its ports exposed (oh my!) is here: I've looked at it and the PMDX-107 manual quite a bit and, honestly, this kind of stuff is not my territory. I'm an industrial designer by trade but I mess with electronics as a hobby so my boss figured I could handle it. I super don't agree. I'd really appreciate any assistance. Edited to add: My PMDX-107 is a Revision D1, if that is in any way significant. I'm pretty sure, but I am not sure enough to risk setting my jobs robot on fire. Thanks. DCM is the digital common and ACM is the analog common. Bob Bob's Corollary: If everything's right and nothing works, double check your assumptions. Please update your browser. We suggest using Google Chrome or Mozilla Firefox.CNC Control systems for the stone countertops processing. The whole machine is with high standard manufacturing process, in the equipment design, dust-free treatment, configuration selection, tool development and other aspects, the machine is perfect. Command Language G code Operating System Mach 3 Interface USB Software capabilities Option: Vectric Aspire, Type3, Ucancam, Artcam, AlphaCam, Powermill, Solidworks,etc. And is fully programmable with speeds from 6000 to 24000 RPM. MACH 3 Controller Mach3 is designed to control the CNC machine. The program is installed on a computer connected to the control machine. Mach3 was developed by American programmers, both for professional and amateur use, so it is the most common software for CNC machines in the world. Using Mach3, it is possible to control the following types of machines: turning, milling, routers, laser and plasma plotter, engraving. Click Here Get More Details The Electronics of the CNC Router All the electrical components are housed and wired in a electrical enclosure. This allows for easy access and service when needed. All wiring is tagged so that when service is required, the customer can easily navigate the cabinet.

    In addition, the cabinet serves as a work bench for the tools required. Vacuum pump The machine comes with a 7.5kw vacuum pump for the sucking the stone, it is powerful enough for suck the machine on the table. XY Axis Hiwin Square Rail XY Axis High Quality Helical Rack Pinion The machine adopts Taiwan Hiwin square rail, which is more than twice durable. And the use of high quality helical rack pinion, makes it powerful. If export to european countries,the wooden box will be fumigated.If container is too tigher,we will use pe film for packing or pack it according to customers special request. Our Company Click to view other related products About Alpha CNC Alpha CNC Co., Ltd. is a factory that specialized in manufacturing and exporting all kinds of cnc routers, such as cnc router machine center with automatic tools changer, multi-process cnc router, multi-head relief cnc router, 3D (Three-dimensional) cylindrical material carving and milling cnc router. We also produce laser engraving cutting machine, fiber laser marking machine, plasma metal cutting machine, waterjet cutting machine and letter bending machine etc. All machines are approved by ISO9001:2008 and CE. We have exported our machines to more than 50 countries, such as USA, Germany, Italy, Canada, Spain, India, Egypt, France, Russia, Brazil, Mexico, Belgium, Chile, South Korea, Uzbekistan, Vietnam, Southeast Asia, and so on. Anyone is interested in our product, welcome to be the partner of Alpha. FAQ. Q1: This is the first time I buy the machine, is it easy to operate. We can provide the operation manual or video for guiding. Q2: How to choose a suitable machine. You can tell us the working piece material, size, and the request of machine function. We can recommend the most suitable machine according to our experience. Q3:How can I trust your company and your products. The whole production procedure will be under regular inspection and strict quality control.

    The complete machine will be tested to make sure they can work very well before being out of factory. The testing video and pictures will be available before delivery. Q4.If machine have any problem after I ordered it, what could I do. Free parts send to you in machine warranty period if machine have any problem. Free after-sales service life for machine, please feel free contact us if your machine have any problem. We will give you 24hours service from phone and skype. Q5. Can I visit your factory. Yes! We greatly welcome customers to visit our factory! Q6. What's your date of delivery. For standard machine, about 15 working days; For customized machine, about 20 working day. Q7.MOQ? Our MOQ is 1 set machine. We could send machine to your country port directly, please tell us your port name. There will be best shipping freight and machine price send to you. Contact Us Now. Cutting at 3mm doc with above settings the inverter pulls about 1.5A. Off the top of my head Gwizard calc estimated the required power to be approx 250w which I assumed it should be more than capable of at that rpm. My question is would a good quality (branded) vfd capable of open loop solve my problems? The spindle stayed quite cool to touch after 5 hours of cutting maybe 30 degrees on the outside jacket. Any help would be great thanks Also had a reserved function which needed to be set to 1235. These manuals are a little bit cryptic Spindle cuts really nicely now.Also had a reserved function which needed to be set to 1235. These manuals are a little bit cryptic Spindle cuts really nicely now. I still feel it is somewhat under powered as kept increasing the width of cut until it would start to stall at 240w (assuming gwizard is correct ofc) see attached picture.I still feel it is somewhat under powered as kept increasing the width of cut until it would start to stall at 240w (assuming gwizard is correct ofc) see attached picture. Mactec54 knows VFD settings so listen to what he is asking.

    Also noticed it has DZB 215DK sticker on the inside, would that indicate a 200 series and maybe not a 300?Also noticed it has DZB 215DK sticker on the inside, would that indicate a 200 series and maybe not a 300? I think I will just buy a new vfd anyway any brands you could recommend?I think I will just buy a new vfd anyway any brands you could recommend? For further information on cookies, please refer to our privacy policy. More infomations about the cookies and further configurations Agree. Our firm has a excellent assurance procedure happen to be established forExcellent quality, reasonable price and customer satisfaction are always pursued. If you are interested in our items, just try to contact us for more details! The inverter max frequency is 400Hz. The inverter comes with an instruction manual. Keep this operating manual handy an d distribute to all users for refere The manuals of our provided manual are unloaded. CNC Modulkit HUANYANG 4.0 KW INVERTER VFD HOW TO SETUP AND WIRE SINGLE PHASE 220V BRIDGEPORT MILL PHASE CONVERTER Features: Different from 1325 CNC Router Machine, the machine was designed with rotary device.And rotary device’s the diameter and length can be made according to your requirements. Instructions and recommendations on how to setup and wire the DZB200 Inverter for spindle motor control. Download 63542313 DZB100 Series User Manual.Getting Started This manual will be helpful in the installation, parameter setting, troubleshooting, and daily maintenance of the AC motor drives. To To guarantee safe operation of the equipment, read the following safety guidelines before connecting power to the AC drives. Keep this operating manual handy and distribute to all users for reference. ! WARNING AT T E N T I O N: Al Alwa ways ys re read ad th this is man manual ual tho thoro roug ughly hly bef befor oree us usin ing g D Z B 1 0 0 se seri ries es AC Mo Moto torr Dr Drive ives. s. DANGER! AC input power must be disconnected before any maintenance.

    WARNING! Do not connect or disconnect wires and connectors while power is applied to the circuit. Maintenance must be performed by qualified technicians. The DC-link capacitor remains charged with a hazardous voltage even after input power is removed. AT T E N T I O N: Grounding the DZB100B drive is done by c o n n e c t i n g t h e E a r t h G r o u n d t o t h e drive ground terminal. These components a r e e s p e c i a l l y s e n s i t i v e t o E S D ( e l e c t r o s t a t i c d i s c h a rg e ). To avoid damage to the drive, do not touch components or the circuit boards until static control precautions have been taken. CAUTION: Ne ve r c on ne ct th e ma in ci rc ui t ou tp ut te rm in al s U, V, an d W di re ct ly to th e AC ma in c i r c u i t p o w e r s u p p l y a s this will damage the drive. CAUTION: Do not apply the antirust to screws for fasten ing drives; Please clean the drives and screws with dry cloth or alcohol, not with synthet ic cleaner. Fasten the screws with washers and rated torque lest the enclosure corners of drives be distorted. This manual is for DZB100 Series AC Motor Drive. -1 - DZB100 DZB1 00 Seri Series es In tr od uc ti on Chapter 1 Introduction T he he p ur ur po po se se o f t hi hi s c ha ha pt pt er er i s t o p ro ro vi vi de de s pe pe ci ci fi fi c, c, y et et s im im pl pl e i nf nf or or ma ma ti ti on on t o unpack, install t he he AC drive. This chapter contains information on the following: 1.1 Receiving, Transportation, and Storage 1.2 Nameplate Information 1.1 Receiving, Storage and Transportation The AC motor drive has gone through rigorous quality control tests at the factory before shipment. After receiving the AC drive, check for the following. Receiving 1.Check to make sure that the package includes an AC drive,the User Manual,dust covers and rubber bushings. 2.Inspect the unit to insure it was not damaged during shipment. 3.